Leave Your Message
60kW 90kW 160kW Charger With Load Shedding For Grid Constrained Locations
Floor Mounted Charger Station
Products Categories
Featured Products

60kW 90kW 160kW Charger With Load Shedding For Grid Constrained Locations

The MIDA 60kW 90kW 160kW DC fast charger uses intelligent load shedding to deliver CCS2 charging at grid-constrained locations without costly utility upgrades, adapting output to available capacity. OEM/ODM customization, global certification support and...

    Product Overview

    The MIDA 60kW 90kW 160kW charger is a grid-connected DC fast charger with intelligent load shedding, engineered specifically for grid-constrained locations. It converts three-phase AC into regulated direct current while continuously adapting its draw to the available electrical capacity, enabling DC fast charging even where the local supply is limited. Three power segments, 60kW, 90kW, and 160kW, let operators match output to the site transformer and the realities of a weak or shared grid connection.

    Load shedding is the defining capability of this charging station. Rather than tripping breakers or demanding costly grid upgrades, the charger dynamically reduces its output when building loads rise and restores full power as capacity frees up. This makes the 60kW 90kW 160kW platform ideal for sites where expanding the electrical service is impractical or expensive. CCS2 connectors ensure broad vehicle compatibility, and OCPP 1.6J communication allows the load management logic to coordinate with building energy systems and the wider charging network.

    Core Advantages

    • Intelligent load shedding automatically throttles output to stay within the available grid capacity, enabling DC fast charging at grid-constrained locations without service upgrades.
    • Three configurable tiers of 60kW, 90kW, and 160kW provide precise alignment between charging power and site electrical headroom.
    • Dynamic power sharing distributes capacity intelligently across multiple sessions, maximizing utilization within a fixed supply limit.
    • CCS2 connectors deliver standardized high-current charging compatible with mainstream electric vehicles.
    • OCPP 1.6J communication integrates with building energy management and demand-response programs for coordinated load control.
    • IP54 enclosure and -30C to +55C operating range support reliable operation in diverse outdoor environments.
    • Conversion efficiency of at least 95% minimizes energy waste, which is especially valuable where capacity is scarce.
    60kW 90kW 160kW Charger With Load Shedding

    Commercial DC Fast Charging

    The floor-standing DC fast charging platform supports rapid vehicle turnaround for commercial operators, public parking and fleet depots, with power sharing matched to site demand.

    60kW 90kW 160kW Charger With Load Shedding

    Dual-Connector Operation

    CCS2 dual-gun output enables two vehicles to charge in parallel while intelligent power balancing protects service continuity and makes better use of available electrical capacity.

    60kW 90kW 160kW Charger With Load Shedding

    Networked Site Management

    OCPP connectivity, RFID, QR and app payment support remote monitoring, tariff control, diagnostics and unattended operation across distributed charging locations.

    60kW 90kW 160kW Charger With Load Shedding

    Outdoor Reliability and Service

    A weather-resistant cabinet, thermal management and modular service architecture support stable operation in demanding outdoor environments and simplify maintenance for charge point operators.

    Technical Specifications

    Parameter Specification
    Rated Output Power 60kW / 90kW / 160kW (configurable)
    Output Voltage Range 150V - 1000V DC
    Connector Standard CCS2
    Input 3-phase 400V AC, 50/60Hz
    Load Management Dynamic load shedding / power sharing
    Peak Efficiency ≥95%
    Ingress Protection IP54
    Operating Temperature -30C to +55C
    Communication OCPP 1.6J, 4G / Ethernet
    Standards IEC 61851, CE

    Application Scenarios

    Grid-constrained urban sites are the primary application for this 60kW 90kW 160kW charger. Older commercial buildings and dense city centers often have limited spare electrical capacity, and the charger's load shedding allows DC fast charging to be installed without an expensive utility upgrade. The system automatically yields power to the building during demand peaks and reclaims it afterward, preserving site stability.

    Retail, office, and mixed-use developments benefit from the same adaptive logic. Where lighting, HVAC, and other loads compete for a fixed supply, the charger's dynamic power sharing ensures EV charging coexists with core building functions. Facility managers can enroll the station in demand-response programs through OCPP 1.6J, further reducing peak charges and supporting grid reliability.

    Rural and edge-of-network locations, where the grid connection is inherently weak, also gain a practical path to DC fast charging. By tailoring output across the 60kW, 90kW, and 160kW tiers and shedding load when necessary, the charger delivers dependable service that would otherwise be impossible on a limited feeder. Its CCS2 connectors and open protocol keep the installation future-ready as capacity improves.

    After-Sales & Support

    MIDA backs the 60kW 90kW 160kW load-shedding DC fast charger with after-sales support focused on maximizing uptime within constrained infrastructure. Remote OCPP 1.6J diagnostics let the service team monitor load management behavior, verify that shedding thresholds are correctly configured, and apply firmware updates without a field visit, ensuring the charger continues to respect site limits.

    Each charging station includes a standard warranty on power modules and core electronics, with extended coverage available for demanding deployments. Regional spare-part stock covers modules, connectors, and control boards to keep replacement lead times short. MIDA additionally provides load-study guidance, commissioning support, and operator training aligned with IEC 61851, helping sites configure load shedding correctly from day one. This combination of adaptive hardware, open-protocol coordination, and expert support makes DC fast charging viable even at the most grid-constrained locations.

    Explore related MIDA solutions: HPC fast EV charger ISO15118 CCS2 DC charging station, Liquid cooled direct-current charger for high-power fleets, Commercial CCS2 direct-current fast charging station, Solar storage EV charging station.

    Frequently Asked Questions

    What power levels are available for these DC fast charging stations?

    MIDA DC fast chargers are offered across the 60kW, 80kW, 90kW, 100kW, 120kW and 160kW range, with 2-3 power options combined in each unit. The 60kW and 80kW models suit workplace, retail and depot charging, while 90kW to 160kW configurations deliver rapid turnaround for highway service areas, fleets and public charging hubs.

    How long does it take to charge an EV with a 60kW to 160kW DC charger?

    Charging time depends on the vehicle battery and selected power. A 60kW charger adds roughly 100km of range in about 15-20 minutes, a 100kW-120kW unit does so in 8-12 minutes, and a 160kW charger can take a compatible EV from 20% to 80% in around 20-30 minutes, making it ideal for high-traffic locations.

    Do the DC charging stations support CCS2 and dual-gun simultaneous charging?

    Yes. The stations use dual CCS2 connectors with intelligent dynamic power sharing, so two electric vehicles can charge at the same time. When only one vehicle is connected, full rated power is delivered to that port; when two are connected, power is balanced automatically between them.

    Are the 60kW-160kW DC chargers OCPP compliant for network management?

    All units are OCPP 1.6J compliant (OCPP 2.0.1 ready) for seamless integration with third-party charging management platforms. Operators get remote monitoring, dynamic pricing, user authentication via RFID, QR and app, and real-time diagnostics for reliable unattended operation.

    Can these DC fast chargers operate outdoors in harsh climates?

    Yes. The floor-standing cabinets carry an IP54/IP55 ingress rating and a wide -30C to +55C operating temperature range, with thermal management and surge protection. This makes them suitable for outdoor parking, highway stations and cold or dusty environments year round.

    What certifications and customization does MIDA offer for these DC chargers?

    MIDA DC fast chargers meet CE, IEC 61851 and relevant safety standards, with OEM/ODM customization of power rating, connector type, enclosure branding and software. Flexible MOQ, global certification support and fast lead times are available for distributors and charge point operators worldwide.

    MAKE AN FREE CONSULTANT

    Your Name*

    Phone Number

    Country

    Remarks*

    rest