Leave Your Message
200kWh 120kW Factory Direct Solar Storage EV Charging Station Wholesale Commercial Infrastructure Procurement Projects
BESS Integrated Charger
Products Categories
Featured Products

200kWh 120kW Factory Direct Solar Storage EV Charging Station Wholesale Commercial Infrastructure Procurement Projects

Integrated MIDA 200kWh 120kW solar-storage EV charger unites PV input, LFP battery and EMS to deliver off-grid capable, peak-shaving DC charging for commercial fleets. Custom OEM/ODM options, global certification and fast lead time available from MIDA.

    Overview

    Purpose-built for demanding depot environments, the MIDA 200kWh 120kW PV BESS charging station integrates photovoltaic harvesting, energy storage, and DC dispensing to cut demand charges through peak shaving. This solar energy storage system stores surplus PV generation in an LFP battery and releases it during costly peak windows. The integrated EV charger supports off-grid resilience, keeping commercial fleet vehicles charging even when the utility supply is limited or temporarily unavailable.

    With 200kWh of usable storage and 120kW of DC output, the system buffers solar surplus during the day and discharges during evening peaks, reducing reliance on the grid and stabilizing site power. The 200kWh LFP battery provides ample dispatchable energy for continuous fleet duty, while the 120kW converter delivers rapid charging sessions. This balance of solar energy storage and fast dispensing makes the integrated EV charger a cost-effective backbone for commercial fleet electrification and demand management. Factory pre-integration shortens deployment timelines, and the compact enclosure fits tight depot layouts. Operators gain predictable energy costs, lower peak demand, and a scalable path to expand charging capacity as fleet size grows over successive project phases.

    Key Advantages

    • An intelligent EMS with peak shaving and load shifting lowers demand charges and optimizes solar self-consumption across the entire charging site for measurable energy savings.
    • MPPT solar input maximizes photovoltaic harvest, feeding renewable energy directly into the storage bank and connected electric vehicles to reduce grid dependence.
    • The CCS2 connector and OCPP 1.6J protocol ensure broad vehicle compatibility and effortless integration with commercial charging network and back-office platforms.
    • A modular, scalable design lets commercial fleet operators expand storage and charging capacity incrementally as their electrification demand grows over time.
    • Remote monitoring and diagnostics reduce on-site maintenance visits and improve uptime across widely distributed charging infrastructure deployments.
    • A robust IP-rated enclosure withstands harsh outdoor conditions, delivering dependable solar energy storage and charging in diverse climates and temperatures.
    200kWh 120kW Factory Direct Solar Storage

    Integrated Solar + Storage Charging

    This integrated PV BESS charging station combines solar generation, lithium battery storage and DC fast charging in one system, delivering clean, resilient energy for commercial EV fleets and microgrids.

    200kWh 120kW Factory Direct Solar Storage

    Peak Shaving and Demand Management

    Intelligent energy management stores low-cost and solar power in the battery and discharges it during peak demand, reducing demand charges, easing grid load and avoiding costly infrastructure upgrades.

    200kWh 120kW Factory Direct Solar Storage

    Off-Grid and Grid-Connected Modes

    Operating both off-grid and grid-connected, the station charges electric vehicles reliably even where grid capacity is limited, making it ideal for remote depots and renewable microgrid deployments.

    200kWh 120kW Factory Direct Solar Storage

    Safe, Rugged and Certified

    Automotive-grade LFP cells, a multi-level BMS, thermal management and an IP54/IP55 weatherproof cabinet ensure safe 24/7 commercial operation, backed by global certification and remote monitoring.

    Technical Specifications

    Battery Capacity 200kWh LFP battery bank
    Charging Power 120kW DC output
    Battery Type LiFePO4 (LFP), high-cycle chemistry
    PCS Bidirectional power conversion system
    Solar Input MPPT photovoltaic tracking input
    Connector CCS2 (DC fast charging)
    Communication Protocol OCPP 1.6J networked charging
    Energy Management Integrated EMS with peak shaving
    Operation Mode Grid-connected and off-grid
    Cycle Life 6000+ cycles at 80% DoD
    Ingress Protection IP54 / IP55 outdoor rated
    Operating Temperature -20°C to +50°C
    Cooling Intelligent forced-air thermal management
    Compliance Standards IEC 61851, IEC 62619

    Application Scenarios

    • Municipal transit and bus depots pursuing zero-emission fleet electrification goals with integrated solar and storage assets.
    • Retail, hospitality, and workplace parking deploying solar PV plus storage to offset energy consumption and attract EV drivers.
    • Commercial fleet depots seeking dependable solar-storage EV charging while minimizing grid demand charges and avoiding costly transformer upgrades.
    • Off-grid and weak-grid sites requiring an integrated EV charger with autonomous, battery-backed operation independent of stable utility supply.
    • Logistics hubs and last-mile delivery centers electrifying growing vehicle fleets through on-site renewable energy storage and fast DC charging.

    Related MIDA energy storage charging solutions: 200kWh 120kW Intelligent Solar Storage EV, 200kWh 120kW CCS2 Direct Current Fast, 200kWh 120kW Liquid Cooled DirectCurrent Charger, 261kWh 120kW Integrated Solar Storage EV.

    Frequently Asked Questions

    What battery capacity and charging power options are available?

    MIDA integrated PV BESS EV charging stations are available in 120kWh/60kW, 200kWh/120kW, 261kWh/120kW, 418kWh/180kW and 522kWh/240kW configurations. The battery capacity (kWh) buffers solar and grid energy, while the charging power (kW) determines how fast connected electric vehicles are charged.

    How does the solar + storage integrated charging station work?

    The system combines photovoltaic input, a lithium iron phosphate (LFP) battery pack, a bidirectional PCS and an intelligent EMS. Solar energy is stored in the battery during the day and released to charge EVs on demand, reducing grid dependence and enabling fast charging even where grid capacity is limited.

    Can the BESS charging station operate off-grid or grid-connected?

    Yes. Both modes are supported. In grid-connected mode it performs peak shaving and demand-charge management; in off-grid mode the solar array and battery storage power EV charging independently, making it ideal for remote fleets, microgrids and areas with weak grid infrastructure.

    How does energy storage reduce charging costs and demand charges?

    The battery charges when electricity is cheap or from solar, then discharges during peak charging periods. This peak-shaving and load-shifting lowers demand charges, avoids costly grid upgrades and maximizes self-consumption of renewable energy, improving the total return on investment.

    Is the lithium battery safe for commercial deployment?

    Yes. MIDA uses automotive-grade LFP (LiFePO4) cells with a multi-level BMS, temperature monitoring, fire suppression and IP54/IP55 weatherproof enclosures, complying with IEC/UL safety standards for reliable 24/7 commercial and fleet operation.

    Where are integrated BESS EV charging stations typically used?

    They are ideal for commercial fleet depots, highway service areas, microgrids, remote and off-grid sites, logistics parks and locations with constrained grid capacity, delivering fast, clean and resilient EV charging with solar self-generation and energy storage.

    MAKE AN FREE CONSULTANT

    Your Name*

    Phone Number

    Country

    Remarks*

    rest